The design values below are as part of a design specification to meet LANTAC System Build Certification for a single domestic three-and-a-half storey dwelling with extremely comfortable margins. For specific designs, please contact this office.
 

   
 
 
 

 
Certification Design Values include:

  • Racking tests to BS-EN 594: 5.25kN/m to 6.51kN/m depending on fastening method.
  • Roof bending tests to BS-EN 380: Moment capacity 5.68kN/m long-term duration, Stiffness capacity EI 125x109Nmm2.
  • Roof creep tests to BS-EN 789: 1.5mm at Total Load of 2kN/m (1/360=3.056mm).
  • Eccentric Vertical Load to BS-EN 380: 20kN per metre run, long term duration.
 