With UK Local Authority Building Control (LANTAC) Certification for domestic dwellings for three-and-a-half stories (room-in-the-roof), the Mantle Building System provides a cost effective, highly insulative thermal shell for builders/ contractors/developers in the housing market, with a 10-year structural warranty from Zurich Insurance Company Building Guarantee, which can be extended for a further five years by the occupiers.
 

  MP Agencies Ltd  
 
   
 

 
Premier Building Guarantees are also available.
Further design parameters can easily be met through the use of a structural engineer.

Attn: Structural Engineers/Professional Designers.
The design values below are as part of a design specification to meet LANTAC System Build Certification for a single domestic three-and-a-half storey dwelling with extremely comfortable margins. For specific designs, please contact this office.
 

   
 
 
 

 
Certification Design Values include:
 

  • Racking tests to BS-EN 594: 5.25kN/m to 6.51kN/m depending on fastening method.
     
  • Roof bending tests to BS-EN 380: Moment capacity 5.68kN/m long-term duration, Stiffness capacity EI 125x109Nmm2.
     
  • Roof creep tests to BS-EN 789: 1.5mm at Total Load of 2kN/m (1/360=3.056mm).
     
  • Concentric Vertical Load: 43kN per metre run, long term duration.
     
  • Eccentric Vertical Load to BS-EN 380: 20kN per metre run, long term duration.